Fluke 1503 Insulation Resistance Meter
The Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting, commissioning, and preventative maintenance applications. Additional features, like the remote probe on these tools save both time and money when performing tests.
Discover the Fluke 1503 Insulation Resistance Meter at Mektronics Australia – your trusted source for quality tools and equipment!
AC/DC Voltage Measurement |
Accuracy |
Range |
600.0 V |
Resolution |
0.1 V |
50 Hz to 400 Hz ± (% of Rdg + Digits) |
± (2 % + 3) |
|
Input impedance |
|
Common mode rejection ratio (1 kΩ unbalanced): |
> 60 dB at dc, 50 or 60 Hz |
|
Overload Protection |
|
Earth bond resistance measurement |
Range/Resolution |
20.00 Ω |
0.01 Ω |
200.0 Ω |
0.1 Ω |
2000 Ω |
1.0 Ω |
20.00 kΩ |
0.01 kΩ |
|
Accuracy |
|
Overload Protection |
|
Open Circuit Test Voltage |
|
Short circuit current |
|
Insulation specifications |
Measurement Range |
1507: |
0.01 MΩ to 10 GΩ |
1503: |
0.01 MΩ to 2000 MΩ |
|
Test voltage |
1507: |
50 V, 100 V, 250 V, 500 V, 1000 V |
1503: |
500 V, 1000V |
|
Test Voltage Accuracy |
|
Short circuit current |
|
Auto Discharge |
Discharge time < 0.5 second for C = 1 µF or less |
|
Live circuit indicator |
Inhibit test if terminal voltage > 30 V prior to initialization of test |
|
Maximum Capacitive Load |
Operable with up to 1 µF load |
|
Measure Accuracy: |
50 V: |
±(3 % + 5) |
100 V: |
±(3 % + 5) |
250 V: |
±(1.5 % + 5) |
500 V: |
±(1.5 % + 5) |
1000 V: |
±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ |
|
General Specifications |
Maximum voltage applied to any terminal: |
|
Storage Temperature |
-40 °C to 60 °C (-40 °F to 140 °F) |
|
Operating Temperature |
-20 °C to 55 °C (-4 °F to 131 °F) |
|
Temperature Coefficient |
0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F) |
|
Relative Humidity |
0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) |
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) |
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) |
|
Vibration |
Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument |
|
Shock |
1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) |
|
Electromagnetic compatibility: |
In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) |
|
Safety |
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) |
|
Certifications: |
CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition |
|
Batteries |
Four AA batteries (NEDA 15A or IEC LR6) |
|
Battery Life |
Insulation test use: |
Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
Resistance measurements: |
Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off. |
|
Size |
5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) |
|
Weight |
|
IP Rating |
|
Altitude |
Operating: |
2000 m CAT IV 600 V, 3000 m CAT III 600 V |
Non-operating (storage): |
12,000 m |
|
Over-range capability: |
|
Included accessories: |
TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe |
|
1507/1503 Insulation Tester Data Sheet
SHIPPING
A delivery and handling charge applies to all orders with the exception of back-ordered items.
Unless otherwise required by Buyer, Seller will make transport arrangements as follows:
For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods
For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.
Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.
Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.
DELIVERY TIME
All quoted delivery or consignment dates are estimates only, given without engagement.
Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.
Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer
a) in the event of a delay in consignment or delivery of goods: or
b) in the event of non delivery.
Goods offered ex-stock by Seller are subject to prior sale.
In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.